Who we are…

Manufacturer and global supplier
of temperature data-collecting
devices used for documenting
environmentally-sensitive
products throughout the cold
chain. ISO 9001:2008 certified.

2.0C

Cold Chain Solutions

Don't Ship without Us!®

•Cryogenic Shipping Containers

Taylor-Wharton Cryogenic Dewars, Refrigerators and Freezers

Taylor-Wharton's advanced range of cryogenic refrigerators and dewars meets your needs - flexibility,efficiency and economy. Our comprehensive series of high-performance refrigerators incorporates durable and lightweight construction with maximum holding times for optimum capacities.


CX & CXR Series


CX & CXR Series

Cryo Express (CX) dry shippers are designed to safely transport a variety of materials at cryogenic temperatures. The unique absorbent material prevents a liquid spill if the unit is tipped over. Storage temperature inside the shipping cavity remains at approximately -190C until the liquid nitrogen evaporates from the absorbent material. The CX Series comply with international regulations applicable to the transport of hazardous goods by road (ADR), rail (RID) and by air (IATA-OACI).

  CX & CXR SERIES
CX100
CXR100
CXR500
Static Holding Time (1) days
24
16
14
Working Time (2) days
17
11
7
Evaporation Rate (1) liters/day
0.18
0.20
0.60
Liquid Nitrogen Capacity liters
4.4
3.3
7.7
Number of Canisters
1
1
N/A
No. of 1.2 ml & 2.0 vials (5/cane) (4)
85
85
500
No. of 1.2 ml & 2.0 vials (6/cane) (4)
102
102
500
No. of 1/2 cc straws (10/cane)
280
280
N/A
No. of 1/2 cc straws (Bulk 2 levels)
980
980
N/A
WEIGHT
lb
kg
lb
kg
lb
kg
Empty
11.7
5.3
11.7
5.3
30
13.6
Full (3)
19.5
8.9
18.3
8.3
41.5
18.7
  DIMENSIONS
inch
mm
inch
mm
inch
mm
Neck Diameter
2.8
71.0
3.6
91.0
8.5
216.0
Overall height
18.4
467.0
19.4
493.0
26.9
683.0
Overall Diameter
9.2
234.0
9.2
234.0
15.5
391.0
  CAPACITY
inch
mm
inch
mm
inch
mm
Canister Diamensions
2.64x11
67x2.79
2.64x11
67x2.79
N/A
N/A
  ACCESSORIES
Padded Carton P/N
3701-9277
N/A
N/A
5 Shelf Rack P/N
N/A
N/A
RS30-9C44
Poly Carb 100 Box
N/A
R24K-9C44
R24K-9C44
Shipping case
CX10-8C00
CX10-8C00
CP19-8C00

Notes:
1. Evaporation rate and static holding time are nominal. Actual rate may be affected by the nature of the contents, atmospheric conditions, container history, and manufacturing tolerances.
2. Work time is an arbitrary, reference-only value to estimate container performance under the actual operating conditions.
3. Without canisters or racks.
4. CXR500 vials are stored in 100 cell boxes.

 

For more information:

Download a PDF of our Cryogenic Shipper Product Brief.

Get Adobe ReaderTo open the PDF files above, you will need Acrobat Reader 9.0 or higher.
Click the icon to download the latest reader software

   rev. Nov-12-2014