Temperature Monitors and Temperature Sensors for Logging and Recording in Critical Environments.
| Model |
EEPROM Memory |
Temperature Range |
Temperature Accuracy |
Features |
Standard Range Low/High |
Dry Ice Apps.
Low/High |
At Zero
At Extremes |
SS |
VM |
CM |
MKT |
Weight |
Warranty |
| Internal sensor |
| mDL4 |
4K |
-10C / 72C
14F / 161F
|
N/A |
0.5C / 1.0F
1.0C / 2.0F
|
NO |
NO |
NO |
NO |
0.3 ounce
8 grams |
12 months |
| mDL8 |
8K |
-20C / 72C
-4F / 161F |
N/A |
0.2C / 0.4F
0.5C / 1.0F |
YES |
NO |
NO |
NO |
0.6 ounce
17 grams |
12 months |
| mDL32 |
32K |
-40C / 72C
-40F / 161F |
N/A |
0.2C / 0.4F
0.5C / 1.0F |
YES |
NO |
YES |
YES |
0.6 ounce
17 grams |
12 months |
| mDL64 |
64K
(variable) |
-40C / 72C
-40F / 161F |
N/A |
0.2C / 0.4F
0.5C / 1.0F |
YES |
YES |
YES |
YES |
0.6 ounce
17 grams |
24 months |
With micro probe |
| mDL8mp |
8K |
-20C / 72C
-4F / 161F |
N/A |
0.2C / 0.4F
0.5C / 1.0F |
YES |
NO |
NO |
NO |
0.6 ounce
17 grams |
12 months |
| mDL32mp |
32K |
-40C / 72C
-40F / 161F |
N/A |
0.2C / 0.4F
0.5C / 1.0F |
YES |
NO |
NO |
YES |
0.6 ounce
17 grams |
12 months |
| mDL64mp |
64K
(variable) |
-40C / 72C
-40F / 161F |
N/A |
0.2C / 0.4F
0.5C / 1.0F |
YES |
YES |
NO |
YES |
0.6 ounce
17 grams |
24 months |
| With standard probe |
| mDL8sp |
8K |
-20C / 72C
-4F / 161F |
N/A |
0.2C / 0.4F
0.5C / 1.0F |
YES |
NO |
NO |
NO |
0.6 ounce
17 grams |
12 months |
| mDL32sp |
32K |
-40C / 72C
-40F / 161F |
N/A |
0.2C / 0.4F
0.5C / 1.0F |
YES |
NO |
NO |
YES |
0.6 ounce
17 grams |
12 months |
| mDL64sp |
64K
(variable) |
-40C / 72C
-40F / 161F |
N/A |
0.2C / 0.4F
0.5C / 1.0F |
YES |
YES |
NO |
YES |
0.6 ounce
17 grams |
24 months |
| With flat probe |
| mDL480fp |
4K |
N/A
|
-80C / 30C
-112F / 86F |
0.2C / 0.4F
0.5C / 1.0F |
NO |
NO |
NO |
YES |
0.6 ounce
17 grams |
12 months |
| mDL880fp |
8K |
N/A
|
-80C / 30C
-112F / 86F |
0.2C / 0.4F
0.5C / 1.0F |
NO |
YES |
YES |
YES |
0.6 ounce
17 grams |
12 months |
| mDL3280fp |
32K |
N/A
|
-80C / 30C
-112F / 86F |
0.2C / 0.4F
0.5C / 1.0F |
NO |
NO |
NO |
YES |
0.6 ounce
17 grams |
12 months |
| mDL6480fp |
64K
(variable) |
N/A |
-80C / 30C
-112F / 86F |
0.2C / 0.4F
0.5C / 1.0F |
NO |
YES |
NO |
YES |
0.6 ounce
20 grams |
24 months |
SS = Stainless Steel Back, VM = Variable Memory, CM = Continuous Memory, MKT = Mean Kinetic Temperature
Required Accessories:
Reader Station
microDL Software
Display Examples
Press the Start button to see the following information
display with each press of the start button: |
 |
 |
 |
 |
1. REC - 8.6C
shows RECording and current temperature
|
2. RUN - 11 D
shows elapsed time in days |
3. MKT - 9.1C
shows mean kinetic temperature (available on silver model only) |
4. HI - 15.2C
shows alarm has occurred and high temperature |
 |
 |
 |
 |
5. LOW - 8.2C
shows alarm has occurred and low temperature |
6. HI HR - 0.3
shows alarm time hours over high threshold
|
7. LOW HR - 1.1
shows alarm time hours over low threshold |
8. 14.9C
Push to return to current temperature |
For more information:
Download a PDF of the microDL Product Guide.
Download a PDF of the microDL Quick Start Guide.
To open the PDF files above, you will need Acrobat Reader 5.0 or higher.